logo

  • P-ISSN1225-0163
  • E-ISSN2288-8985
  • SCOPUS, ESCI, KCI

논문 상세

Home > 논문 상세
  • P-ISSN 1225-0163
  • E-ISSN 2288-8985

논문 상세

    Liquid chromatographic enantioseparation of several amino acids as nitrobenzoxadiazole derivatives on polysaccharide trisphenylcarbamate derived chiral stationary phases

    Liquid chromatographic enantioseparation of several amino acids as nitrobenzoxadiazole derivatives on polysaccharide trisphenylcarbamate derived chiral stationary phases

    분석과학 / Analytical Science and Technology, (P)1225-0163; (E)2288-8985
    2023, v.36 no.4, pp.143-151
    https://doi.org/10.5806/ast.2023.36.4.143
    AdhikariSuraj(Suraj Adhikari) (College of Pharmacy, Chosun University)
    BhandariAlisha(Alisha Bhandari) (College of Pharmacy, Chosun University)
    LeeWonjae(Wonjae Lee) (College of Pharmacy, Chosun University)

    Abstract

    Considering the greater role of α-amino acids in our daily lives, the enantiomer resolution of seven α-amino acids derivatized with fluorogenic reagent (4-fluoro-7-nitro-2,1,3-benzoxadiazole, NBD-F) by chiral HPLC on amylose or cellulose trisphenylcarbamate derived chiral stationary phases (CSPs) under simultaneous ultraviolet (UV) and fluorescence (FL) detection was performed. The degree of enantioseparation and resolution was affected by nature and selector backbones of the CSPs as well as the kind of amino acids. Baseline enantiomer separation and resolutions were observed for the enantiomers of all analytes as NBD derivatives especially on coated type amylose tris(3,5-dimethylphenylcarbamate) derived CSPs (Chiralpak AD-H and Lux Amylose-1). The other CSPs also showed good enantioselectivity except for the CSPs (Chiralpak IB, Chiralcel OD-H and Lux Cellulose-1) having cellulose tris(3,5-dimethylphenylcarbamate) as chiral selectors. The developed analytical chiral method was applied to determine the enantiomeric purity of seven commercially available L-α-amino acids and the impurities as D-forms were found to be in the range 0.08-0.87 %, respectively. The intra- and interday accuracy and precision assays showed high accuracy and precision of the developed analytical method. This chiral HPLC method for the enantiomer resolution of amino acids using fluorescent derivatization could be useful for the determination of enantiomeric purity of pharmaceuticals and biological study for amino acid type compounds among chiral drugs.

    keywords
    <TEX>${\alpha}$</TEX>-amino acids, chiral stationary phase, enantiomer separation, fluorescence, nitrobenzoxadiazole derivative

    그래픽 초록

    AST-2023-008_R1_P_Graphical Abstract_001.jpg

    투고일Received
    2023-02-08
    수정일Revised
    2023-03-31
    게재확정일Accepted
    2023-04-06
    출판일Published
    2023-08-25
    상단으로 이동

    분석과학