Determination of Tributyl Phosphate Degradation Products by Ion Chromatography

Analytical Science and Technology / Analytical Science and Technology, (P)1225-0163; (E)2288-8985
2002, v.15 no.4, pp.329-334





Abstract

Tributyl phosphate(TBP) is used in solvent extraction process for radioactive waste. This compound may be degraded to dibutyl phosphate($DBP^-$), monobutyl phosphate($MBP^{2-}$) and ${PO_4}^{3-}$ by radioactive material. Amount of $DBP^-$ and $MBP^{2-}$ in TBP must be monitored because they production of these compounds means degradation of which leads to a decrease in the extraction yield. Retention behavior for $DBP^-$, $MBP^{2-}$, $F^-$, $Cl^-$, ${NO_2}^-$, ${NO_3}^-$, ${SO_4}^{2-}$ and ${PO_4}^{3-}$ are studied with AS4A-SC(Dionex) analytical column and $Na_2CO_3$/NaOH eluent by Ion chromatography. Optimum condition for these anions is 2 mM $Na_2CO_3$/1 mM NaOH eluent. All anions by this condition is well separated within 15min. Dynamic range is $10{\mu}g/mL$ - $100{\mu}g/mL$ for DBP and $5{\mu}g/mL$ - $50{\mu}g/mL$ for $MBP^{2-}$, respectively. The Detection limit for AS4A-SC are $1{\mu}g/mL$ for $DBP^-$ and $0.5{\mu}g/mL$ for $MBP^{2-}$ in this system with a $25{\mu}L$ sample loop.

keywords
Ion chromatography, TBP, Gamma degradation, Determination of <TEX>$DBP^-$</TEX> and <TEX>$MBP^{2-}$</TEX>