바로가기메뉴

본문 바로가기 주메뉴 바로가기
 

Journal of the Korean Association of Oral and Maxillofacial Surgeons

  • P-ISSN2234-7550
  • E-ISSN2234-5930
  • SCOPUS, KCI, ESCI

Evaluation of the efficacy of salmon calcitonin nasal spray on bone healing following surgical removal of impacted third molar: a randomized controlled study

Journal of the Korean Association of Oral and Maxillofacial Surgeons / Journal of the Korean Association of Oral and Maxillofacial Surgeons, (P)2234-7550; (E)2234-5930
2026, v.52 no.2, pp.73-79
https://doi.org/10.5125/jkaoms.2026.52.2.73
Harni Nirmal (Department of Oral and Maxillofacial Surgery, Madha Dental College and Hospital, Chennai, India)
Satheesh Chandran (Department of Oral and Maxillofacial Surgery, Madha Dental College and Hospital, Chennai, India)
Department of Oral and Maxillofacial Surgery, Madha Dental College and Hospital, Chennai, India
Deenadayalan Narasimman (Department of Oral and Maxillofacial Surgery, Madha Dental College and Hospital, Chennai, India)
Karthik Kattur Premkumar (Department of Oral and Maxillofacial Surgery, Madha Dental College and Hospital, Chennai, India)
Balamurugan Rajendran (Department of Dentistry, RYA Madras Cosmo Foundation Hospital, Chennai, India)
George Samyo Stephenson (Department of Oral and Maxillofacial Surgery, Madha Dental College and Hospital, Chennai, India)

Abstract

Objectives: To assess the efficacy of salmon calcitonin spray on postoperative pain, serum calcitonin levels, and bone healing after surgical removal of impacted mandibular third molar. Materials and Methods: This prospective study included 100 patients who required surgical removal of impacted mandibular third molars under local anesthesia. Group I included 50 patients who received intranasal serum calcitonin spray, and Group II included 50 patients who did not receive serum calcitonin spray. The postoperative pain was evaluated on the 1st, 3rd and 7th days. The serum osteocalcin levels were assessed at 1 month, and bone density was evaluated at the 3rd month postoperatively. Results: The severity of pain was less in Group I on days 3, and 7 postoperatively compared to Group II (P<0.05). The postoperative serum calcitonin level was higher in Group I compared to Group II (P<0.05), and the bone density was greater in Group I when compared to Group II evaluated at the 3rd month postoperatively (P<0.05). Conclusion: The results of our study delineate that Group I patients had better efficacy in controlling pain and improved bone healing with calcitonin nasal spray when compared to Group II patients.

keywords
Impacted tooth, Calcitonin, Nasal spray, Pain, Osteocalcin

Journal of the Korean Association of Oral and Maxillofacial Surgeons